Architecture, Building And Environmental Design
Comprehensive Wind Analysis of 202 Meters WTC Tower in Shiraz Using CFD Simulations
This project was performed in 2006 with the aim of wind analysis for 202 meters WTC tower in Shiraz. With developments of software and hardware industries, a professional team using CFD simulations can handle the tower wind analysis in real scale and inaccurate and time consuming wind tunnel tests are completely unnecessary. Computer aided analysis can be used to verify the effect of different parameters in short time and low costs. In this project the effect of different parameters were clarified with a close cooperation to architecture team.
Proper angle Determination of the building and the architecture with the consideration of wind direction for pedestrian comfort and wind circulation minimization to control the noise pollution.
Helicopter landing requirements in critical stormy conditions.
Weather conditions requirements for using the outdoor pool at 140 meters height.
Window opening design with the consideration of wind direction for residents comfort.
Architectural design with the consideration of prevailing wind angle for concert on sloped roof.
 

CFD Analysis of Wind Flow in a Dense Urban Area
This project was performed in 2012 to study the effect of Urban Architecture on air pollution trap. The effect of pollution from stationary and mobile sources in various wind conditions was studied using CFD simulations. In this project a large and dense urban area was modeled in Arya Alborz Company and numerical simulations for different situations such as wind velocity and direction were studied. Based on comprehensive simulations of this project, deep insight into urban architecture effect on air pollution management was produced in Arya Alborz engineering group.

Air Flow and Heat Transfer Analysis in a Building Block Using CFD Simulations
This project was executed in 2013 to study the city block architecture design with the consideration of energy consumption optimization. With proper design of wind break, energy loss can be minimized during winter. In this regard, the exact geometry of a 40-storey tower is created. Considering the wind speed variations with height, heat dissipation increases on surfaces. Precise CFD simulations for air flow around the tower and thermal analysis inside the tower was performed. Based on comprehensive simulations and sensitivity analysis of different parameters, deep insight into building energy optimization using CFD simulations was developed in Arya Alborz engineering group.

Ventilation Simulation in a Hotel Lobby
This project was performed in 2013 to study the effect of different parameters on comfort and saving energy. Today in industrialized countries architecture is innovated with the consideration of reducing energy consumption. In this project different strategies for energy consumption reduction were studied using CFD simulations and a deep insight into energy optimization in buildings was provided in Arya Alborz Company.